• Harvey

Interaction between UPS and PDU


Customer

智能型不斷電系統使用者

Smart UPS users

Problem

當電力中斷時,UPS接續供電。但由於UPS電力容量有限,必須關閉某些次要設備,以便延長UPS供電時間,使重要設備持續運行。 但要如何關閉某些次要設備?

When power failure, UPS will continue to supply power, however, due to the limited capacity of the UPS, some secondary equipment can be shut down in order to extend the UPS power supply time and keep the important equipment running.

But how do I turn off some secondary devices?

Solution

透過UPS的網路管理介面,使用者設定SNMP Trap,發送至 DGP Cloud PDU。當Cloud PDU 收到指定Trap 後,會觸發預設的事件回應設定,將指定的輸出開啟或關閉,達到UPS將低耗電的效果。

Through the UPS's network management interface, the user sets SNMP Trap and sends it to the DGP Cloud PDU. When the Cloud PDU receives the specified Trap, it will trigger the event action setting, it will turn the specified output on or off, and reaches the effect of low power consumption.

Cloud PDU web interface

Benefits (Result)

降低UPS耗電量。使電力中斷時,以延長重要設備用電時間

Reduce UPS power consumption. When the power fails, it can extend the important equipment power usage.

發送SNMP Trap 至DGP Cloud PDU,藉以控制指定輸出開關,同樣可以運用於其他IT設備

Send SNMP Trap to DGP Cloud PDU to control the specified output switch, the same mode can also be used for other IT equipment.